이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
P51-1000-A-AA-I36-20MA-000-000

P51-1000-A-AA-I36-20MA-000-000

Basic Information Overview

Category

The P51-1000-A-AA-I36-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial processes

Package

The P51-1000-A-AA-I36-20MA-000-000 comes in a durable and protective packaging to ensure safe transportation and storage.

Essence

The essence of this product lies in its ability to accurately measure and transmit pressure data in challenging industrial environments.

Packaging/Quantity

The product is typically packaged individually and the quantity may vary based on customer requirements.

Specifications

  • Pressure Range: 0-1000 psi
  • Output: 4-20 mA
  • Accuracy: ±0.5% of full scale
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel

Detailed Pin Configuration

The detailed pin configuration of P51-1000-A-AA-I36-20MA-000-000 includes: 1. Power supply input (+) 2. Power supply input (-) 3. Signal output 4. Ground

Functional Features

  • Pressure sensing technology
  • Signal conditioning circuitry
  • Output signal transmission
  • Overpressure protection

Advantages

  • High accuracy ensures precise pressure measurement
  • Robust construction for reliability in harsh industrial environments
  • Wide operating temperature range allows for versatile use
  • Compatibility with various industrial processes enhances its applicability

Disadvantages

  • May require periodic calibration
  • Initial cost may be higher compared to some alternatives

Working Principles

The P51-1000-A-AA-I36-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as a standardized 4-20 mA output.

Detailed Application Field Plans

This pressure transmitter is suitable for a wide range of industrial applications including: - Hydraulic systems - Process control - Industrial machinery - Manufacturing processes

Detailed and Complete Alternative Models

Some alternative models to consider include: - P51-2000-B-BB-I36-20MA-000-000 - P51-500-C-CC-I36-20MA-000-000 - P51-250-D-DD-I36-20MA-000-000

In conclusion, the P51-1000-A-AA-I36-20MA-000-000 industrial pressure transmitter offers high accuracy, robustness, and versatility, making it a valuable component in various industrial settings.

[Word count: 324]

기술 솔루션에 P51-1000-A-AA-I36-20MA-000-000 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the application of P51-1000-A-AA-I36-20MA-000-000?

    • The P51-1000-A-AA-I36-20MA-000-000 is a pressure transducer commonly used in industrial and technical applications to measure and transmit pressure readings.
  2. What are the typical industries that use P51-1000-A-AA-I36-20MA-000-000?

    • Industries such as oil and gas, automotive, aerospace, manufacturing, and HVAC commonly utilize the P51-1000-A-AA-I36-20MA-000-000 for pressure monitoring and control.
  3. What is the operating range of P51-1000-A-AA-I36-20MA-000-000?

    • The P51-1000-A-AA-I36-20MA-000-000 typically operates within a specified pressure range, such as 0-1000 psi, making it suitable for various pressure measurement requirements.
  4. How does P51-1000-A-AA-I36-20MA-000-000 interface with control systems?

    • The P51-1000-A-AA-I36-20MA-000-000 often features a 4-20mA output signal, allowing it to interface with standard control systems and PLCs for real-time pressure monitoring and feedback.
  5. What are the environmental considerations for using P51-1000-A-AA-I36-20MA-000-000?

    • The P51-1000-A-AA-I36-20MA-000-000 is designed to withstand harsh environmental conditions, including temperature variations, humidity, and exposure to certain chemicals or fluids.
  6. Can P51-1000-A-AA-I36-20MA-000-000 be used in hazardous areas?

    • Depending on the model and certifications, the P51-1000-A-AA-I36-20MA-000-000 may be suitable for use in hazardous areas, meeting standards such as ATEX or IECEx for explosive atmospheres.
  7. What are the installation considerations for P51-1000-A-AA-I36-20MA-000-000?

    • Proper mounting, sealing, and electrical connections are essential for installing the P51-1000-A-AA-I36-20MA-000-000 to ensure accurate and reliable pressure measurements.
  8. How can P51-1000-A-AA-I36-20MA-000-000 be calibrated?

    • Calibration procedures for the P51-1000-A-AA-I36-20MA-000-000 typically involve applying known pressures and adjusting the transducer's output to match the expected readings.
  9. What maintenance is required for P51-1000-A-AA-I36-20MA-000-000?

    • Regular inspection, cleaning, and calibration checks are recommended to maintain the performance and accuracy of the P51-1000-A-AA-I36-20MA-000-000 over time.
  10. Are there any special considerations when integrating P51-1000-A-AA-I36-20MA-000-000 into a larger system?

    • Integration may require compatibility with existing communication protocols, power supplies, and data acquisition systems, so careful planning and coordination with other components are important.