이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
P51-1000-A-I-MD-5V-000-000

P51-1000-A-I-MD-5V-000-000

Product Overview

Category

The P51-1000-A-I-MD-5V-000-000 belongs to the category of precision sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High precision
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The sensor is typically packaged in a durable housing suitable for industrial environments.

Essence

The essence of the P51-1000-A-I-MD-5V-000-000 lies in its ability to provide accurate and reliable pressure measurements in challenging conditions.

Packaging/Quantity

The sensor is usually available as a single unit, packed securely to prevent damage during transportation and storage.

Specifications

  • Pressure Range: 0-1000 psi
  • Output: 5V DC
  • Accuracy: ±0.5%
  • Operating Temperature: -40°C to 125°C
  • Media Compatibility: Compatible with most gases and liquids

Detailed Pin Configuration

The detailed pin configuration of the P51-1000-A-I-MD-5V-000-000 includes power supply, ground, and output signal pins, ensuring easy integration into existing systems.

Functional Features

  • High accuracy and repeatability
  • Built-in overpressure protection
  • Low power consumption
  • Compact design for easy installation
  • Compatibility with various industry-standard interfaces

Advantages and Disadvantages

Advantages

  • Precise and reliable pressure measurements
  • Suitable for harsh industrial environments
  • Low maintenance requirements
  • Wide operating temperature range
  • Compatibility with diverse media

Disadvantages

  • Higher initial cost compared to some traditional pressure sensors
  • Requires careful handling due to its precision components

Working Principles

The P51-1000-A-I-MD-5V-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an electrical signal that represents the measured pressure.

Detailed Application Field Plans

The P51-1000-A-I-MD-5V-000-000 is widely used in industries such as: - Automotive manufacturing - Aerospace - Oil and gas - Industrial automation - Hydraulic systems

Its high precision and robustness make it suitable for critical applications where accurate pressure measurement is essential for operational safety and efficiency.

Detailed and Complete Alternative Models

Some alternative models to the P51-1000-A-I-MD-5V-000-000 include: - P51-500-A-I-MD-5V-000-000 (500 psi range) - P51-2000-A-I-MD-5V-000-000 (2000 psi range) - P51-1000-A-I-MD-10V-000-000 (10V output)

These alternative models offer varying pressure ranges and output options to cater to different application requirements.

This comprehensive entry provides a detailed understanding of the P51-1000-A-I-MD-5V-000-000, including its specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

기술 솔루션에 P51-1000-A-I-MD-5V-000-000 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the P51-1000-A-I-MD-5V-000-000?

    • The P51-1000-A-I-MD-5V-000-000 is a pressure sensor designed for industrial applications, capable of measuring pressure and providing accurate readings.
  2. What are the typical operating conditions for the P51-1000-A-I-MD-5V-000-000?

    • The P51-1000-A-I-MD-5V-000-000 is designed to operate within a temperature range of -40°C to 85°C and can withstand pressures up to 1000 psi.
  3. How is the P51-1000-A-I-MD-5V-000-000 installed?

    • The sensor can be installed using standard mounting techniques, such as threaded or flanged connections, depending on the specific application requirements.
  4. What output signals does the P51-1000-A-I-MD-5V-000-000 provide?

    • This sensor typically provides a 0-5V analog output signal, making it compatible with a wide range of data acquisition systems and controllers.
  5. Is the P51-1000-A-I-MD-5V-000-000 suitable for use in hazardous environments?

    • Yes, the P51-1000-A-I-MD-5V-000-000 is available with intrinsically safe certifications, making it suitable for use in hazardous locations.
  6. Can the P51-1000-A-I-MD-5V-000-000 be used for liquid and gas pressure measurements?

    • Yes, this sensor is suitable for measuring both liquid and gas pressures, making it versatile for various industrial applications.
  7. What is the accuracy of the P51-1000-A-I-MD-5V-000-000?

    • The sensor typically offers high accuracy, with a percentage of full-scale accuracy ranging from 0.25% to 0.5%, depending on the model.
  8. Does the P51-1000-A-I-MD-5V-000-000 require calibration?

    • Yes, periodic calibration is recommended to ensure the sensor maintains its accuracy and reliability over time.
  9. What are the common failure modes of the P51-1000-A-I-MD-5V-000-000?

    • Common failure modes include electrical issues, sensor drift, and physical damage due to environmental factors.
  10. Are there any special considerations for integrating the P51-1000-A-I-MD-5V-000-000 into a technical solution?

    • It's important to consider factors such as mounting orientation, environmental conditions, and compatibility with the existing control and monitoring systems when integrating the sensor into a technical solution.