Product Overview

Category

The P51-50-S-F-I36-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial fluids

Package

The P51-50-S-F-I36-20MA-000-000 comes in a durable housing suitable for industrial environments.

Essence

The essence of this product lies in its ability to accurately measure and transmit pressure data in challenging industrial settings.

Packaging/Quantity

Each unit is packaged individually and is available for purchase as a single item.

Specifications

  • Pressure Range: 0-50 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel
  • Electrical Connection: M12 connector

Detailed Pin Configuration

The detailed pin configuration of the P51-50-S-F-I36-20MA-000-000 is as follows: 1. Power Supply (+) 2. Power Supply (-) 3. Signal Output 4. Not connected

Functional Features

  • Accurate pressure measurement
  • Linear 4-20 mA output
  • Overpressure protection
  • Easy installation and setup

Advantages

  • High accuracy and reliability
  • Suitable for harsh industrial environments
  • Easy integration with control systems
  • Long-term stability

Disadvantages

  • Limited pressure range
  • Requires compatible signal conditioning equipment
  • Higher initial cost compared to some alternatives

Working Principles

The P51-50-S-F-I36-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as a 4-20 mA current proportional to the measured pressure.

Detailed Application Field Plans

This pressure transmitter is ideal for use in various industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery

Detailed and Complete Alternative Models

Some alternative models to consider include: - P51-100-S-A-I36-20MA-000-000 - P51-200-S-B-I36-20MA-000-000 - P51-500-S-C-I36-20MA-000-000

In conclusion, the P51-50-S-F-I36-20MA-000-000 industrial pressure transmitter offers high accuracy and reliability, making it suitable for demanding industrial environments. Its robust construction and wide operating temperature range make it a valuable component in various industrial applications. While it has certain limitations, its performance and functionality make it a preferred choice for accurate pressure measurement and transmission.

기술 솔루션에 P51-50-S-F-I36-20MA-000-000 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the P51-50-S-F-I36-20MA-000-000 used for?

    • The P51-50-S-F-I36-20MA-000-000 is a pressure transducer commonly used to measure and transmit pressure readings in various technical applications.
  2. What is the operating range of the P51-50-S-F-I36-20MA-000-000?

    • The operating range of the P51-50-S-F-I36-20MA-000-000 is typically from 0 to 50 psi, making it suitable for a wide range of pressure measurement tasks.
  3. How does the P51-50-S-F-I36-20MA-000-000 interface with other systems?

    • The P51-50-S-F-I36-20MA-000-000 typically interfaces with other systems using a 4-20mA output signal, allowing for easy integration into control and monitoring systems.
  4. What are the environmental considerations for using the P51-50-S-F-I36-20MA-000-000?

    • The P51-50-S-F-I36-20MA-000-000 is designed to operate within specific temperature and humidity ranges, so it's important to consider these factors when integrating it into a technical solution.
  5. Can the P51-50-S-F-I36-20MA-000-000 be used in hazardous environments?

    • Yes, the P51-50-S-F-I36-20MA-000-000 is available in intrinsically safe versions, allowing it to be used in hazardous environments where explosive gases or dust may be present.
  6. What kind of calibration does the P51-50-S-F-I36-20MA-000-000 require?

    • The P51-50-S-F-I36-20MA-000-000 typically requires periodic calibration to ensure accurate pressure measurements, and this can be done using standard calibration equipment.
  7. Is the P51-50-S-F-I36-20MA-000-000 suitable for use in industrial applications?

    • Yes, the P51-50-S-F-I36-20MA-000-000 is commonly used in industrial applications such as manufacturing, process control, and HVAC systems.
  8. What are the typical installation requirements for the P51-50-S-F-I36-20MA-000-000?

    • The P51-50-S-F-I36-20MA-000-000 is typically installed using standard NPT fittings and should be mounted in a location that provides good access for maintenance and calibration.
  9. Can the P51-50-S-F-I36-20MA-000-000 be used for both liquid and gas pressure measurements?

    • Yes, the P51-50-S-F-I36-20MA-000-000 is suitable for measuring both liquid and gas pressures, making it versatile for various technical solutions.
  10. What are some common troubleshooting steps for the P51-50-S-F-I36-20MA-000-000?

    • Common troubleshooting steps for the P51-50-S-F-I36-20MA-000-000 include checking for proper electrical connections, verifying calibration, and inspecting for any physical damage or obstructions.