Product Overview

Category

The P51-500-A-AA-P-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-500-A-AA-P-20MA-000-000 lies in its ability to accurately measure and transmit pressure data in industrial settings.

Packaging/Quantity

The product is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 85°C
  • Pressure Connection: 1/4" NPT male

Detailed Pin Configuration

The detailed pin configuration of the P51-500-A-AA-P-20MA-000-000 includes: - Power supply input (+) - Power supply input (-) - Signal output - Ground

Functional Features

  • High precision pressure measurement
  • Linear 4-20 mA output signal
  • Built-in temperature compensation
  • Overpressure protection
  • Easy installation and maintenance

Advantages

  • Accurate and reliable pressure measurement
  • Compatibility with various industrial fluids
  • Long-term stability and durability
  • Easy integration into existing systems

Disadvantages

  • Limited pressure range compared to some other models
  • May require additional accessories for certain installations

Working Principles

The P51-500-A-AA-P-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as a 4-20 mA output proportional to the measured pressure.

Detailed Application Field Plans

The P51-500-A-AA-P-20MA-000-000 is suitable for a wide range of industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery - HVAC systems

Detailed and Complete Alternative Models

Some alternative models to the P51-500-A-AA-P-20MA-000-000 include: - P51-100-A-AB-H-I-20MA-000-000 - P51-1000-A-AA-P-20MA-000-000 - P51-250-A-AA-P-20MA-000-000

In conclusion, the P51-500-A-AA-P-20MA-000-000 is a high-precision industrial pressure transmitter with a wide range of applications and robust characteristics, making it an essential component in various industrial processes.

Word Count: 346

기술 솔루션에 P51-500-A-AA-P-20MA-000-000 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the application of P51-500-A-AA-P-20MA-000-000?

    • The P51-500-A-AA-P-20MA-000-000 is a pressure transducer commonly used in industrial and technical applications to measure and transmit pressure readings.
  2. What is the operating range of P51-500-A-AA-P-20MA-000-000?

    • The operating range of P51-500-A-AA-P-20MA-000-000 is typically from 0 to 500 psi, making it suitable for a wide range of pressure measurement tasks.
  3. How does P51-500-A-AA-P-20MA-000-000 interface with control systems?

    • P51-500-A-AA-P-20MA-000-000 typically interfaces with control systems through a 4-20 mA output signal, allowing for easy integration into various control and monitoring systems.
  4. What are the environmental considerations for using P51-500-A-AA-P-20MA-000-000?

    • P51-500-A-AA-P-20MA-000-000 is designed to operate in harsh industrial environments and can withstand temperature variations, humidity, and exposure to certain chemicals depending on its specifications.
  5. Can P51-500-A-AA-P-20MA-000-000 be used in hazardous areas?

    • Yes, there are versions of P51-500-A-AA-P-20MA-000-000 available that are certified for use in hazardous areas, meeting specific safety standards such as ATEX or IECEx.
  6. What are the typical applications for P51-500-A-AA-P-20MA-000-000?

    • P51-500-A-AA-P-20MA-000-000 is commonly used in hydraulic systems, industrial machinery, process control, HVAC systems, and other applications requiring accurate pressure measurement and control.
  7. What is the accuracy of P51-500-A-AA-P-20MA-000-000?

    • The accuracy of P51-500-A-AA-P-20MA-000-000 is typically specified by the manufacturer and can range from 0.25% to 1% of full scale, depending on the model and calibration.
  8. Can P51-500-A-AA-P-20MA-000-000 be submerged in liquids?

    • There are models of P51-500-A-AA-P-20MA-000-000 designed for submersion in liquids, but it's important to verify the specific model's capabilities and limitations.
  9. How do you calibrate P51-500-A-AA-P-20MA-000-000?

    • Calibration procedures for P51-500-A-AA-P-20MA-000-000 typically involve applying known pressures and adjusting the output signal to match the expected values, following the manufacturer's guidelines.
  10. What maintenance is required for P51-500-A-AA-P-20MA-000-000?

    • Regular inspection, cleaning, and calibration checks are recommended to ensure the continued accuracy and reliability of P51-500-A-AA-P-20MA-000-000 in technical solutions.