이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
P51-500-A-AD-P-20MA-000-000

P51-500-A-AD-P-20MA-000-000

Basic Information Overview

Category

The P51-500-A-AD-P-20MA-000-000 belongs to the category of industrial pressure transducers.

Use

It is used for measuring and transmitting pressure readings in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Long-term stability

Package

The P51-500-A-AD-P-20MA-000-000 is typically packaged in a durable housing suitable for industrial environments.

Essence

The essence of this product lies in its ability to accurately measure and transmit pressure data in challenging industrial settings.

Packaging/Quantity

The product is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 85°C
  • Supply Voltage: 10-30 VDC
  • Pressure Connection: 1/4" NPT male

Detailed Pin Configuration

The detailed pin configuration for the P51-500-A-AD-P-20MA-000-000 is as follows: - Pin 1: Power Supply + - Pin 2: Power Supply - - Pin 3: Signal Output +

Functional Features

  • High precision pressure measurement
  • Linear 4-20 mA output signal
  • Built-in temperature compensation
  • Overpressure protection

Advantages

  • Reliable and accurate pressure measurement
  • Suitable for harsh industrial environments
  • Compatibility with standard control systems
  • Long-term stability and durability

Disadvantages

  • Higher initial cost compared to some alternatives
  • Requires proper installation and calibration for optimal performance

Working Principles

The P51-500-A-AD-P-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal using a sensing element, which is then linearly converted to a 4-20 mA output proportional to the pressure.

Detailed Application Field Plans

Industrial Automation

  • Monitoring hydraulic systems
  • Pressure control in manufacturing processes

Oil & Gas

  • Wellhead pressure monitoring
  • Pipeline pressure measurement

Aerospace

  • Aircraft hydraulic system pressure monitoring

Detailed and Complete Alternative Models

  • Model A: P51-250-B-AD-P-20MA-000-000
  • Model B: P51-1000-C-AD-P-20MA-000-000
  • Model C: P51-500-A-BD-P-20MA-000-000

This concludes the comprehensive overview of the P51-500-A-AD-P-20MA-000-000 industrial pressure transducer, including its basic information, specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models.

기술 솔루션에 P51-500-A-AD-P-20MA-000-000 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the application of P51-500-A-AD-P-20MA-000-000?

    • The P51-500-A-AD-P-20MA-000-000 is a pressure transducer commonly used in industrial and technical applications to measure and transmit pressure readings.
  2. What is the operating range of P51-500-A-AD-P-20MA-000-000?

    • The operating range of P51-500-A-AD-P-20MA-000-000 is typically from 0 to 500 psi, making it suitable for a wide range of pressure measurement tasks.
  3. How does P51-500-A-AD-P-20MA-000-000 interface with control systems?

    • P51-500-A-AD-P-20MA-000-000 interfaces with control systems through a 4-20mA output signal, allowing for easy integration into various control and monitoring systems.
  4. What are the typical industries that use P51-500-A-AD-P-20MA-000-000?

    • P51-500-A-AD-P-20MA-000-000 is commonly used in industries such as manufacturing, automotive, aerospace, oil and gas, and HVAC for pressure monitoring and control.
  5. Can P51-500-A-AD-P-20MA-000-000 be used in harsh environments?

    • Yes, P51-500-A-AD-P-20MA-000-000 is designed to withstand harsh environmental conditions, including high temperatures and corrosive atmospheres.
  6. What is the accuracy of P51-500-A-AD-P-20MA-000-000?

    • The accuracy of P51-500-A-AD-P-20MA-000-000 is typically within ±0.5% of full scale, ensuring reliable and precise pressure measurements.
  7. Does P51-500-A-AD-P-20MA-000-000 require calibration?

    • Yes, regular calibration is recommended for P51-500-A-AD-P-20MA-000-000 to maintain its accuracy and performance over time.
  8. Is P51-500-A-AD-P-20MA-000-000 compatible with different pressure media?

    • P51-500-A-AD-P-20MA-000-000 is compatible with a variety of pressure media, including gases and liquids, making it versatile for different applications.
  9. What are the installation requirements for P51-500-A-AD-P-20MA-000-000?

    • Proper mounting and sealing techniques should be followed to ensure accurate readings and longevity of the transducer in the application.
  10. Can P51-500-A-AD-P-20MA-000-000 be used for both static and dynamic pressure measurements?

    • Yes, P51-500-A-AD-P-20MA-000-000 is suitable for measuring both static and dynamic pressures, providing flexibility in various technical solutions.